Consent form For explaining the procedure, risks, and benefits to the patient and getting their permission to proceed.
Timeout Sheet A checklist for doing timout.
lidocaine 1% without epinephrine, 3 mL For numbing the arm prior to insertion.
5 mL Syringe For injecting lidocaine.
18 gauge needle For drawing up lidocaine into the syringe. Do not let the patient see this needle.
25 to 27.5 gauge needle A small and friendly needle for injecting lidocaine.
Chucks pad Put this under the patient's arm in case of bleeding.
Paper Measuring Tape For measuring the location of the insertion site.
Derm Marker For marking the insertion site.
Chloraprep An antibacterial solution for cleaning the skin prior to insertion injection of lidocaine or insertion of the nexplanon.
Nexplanon Kit The device that is used for inserting the nexplanon.
x2 Sterile Gauze, 2" x 2" For bandaging the wound, holding pressure, and cleaning the wound.
Alcohol Prep Pads x 2 For cleaning off any blood after the insertion is complete.
Steri-Strips For cutting steri-strips prior to application. Cut in half, hamburger style.
Coban For wrapping the wound after insertion.